Figure 4-15 UART configuration
Parity
Parity can be none, even or odd. The factory default setting is none.
Stop bits
Stop bits can be between 1 bit and 2 bits. The factory default setting is 1 bit.
Flow control
The factory default setting of the flow control is None. Software Flow Control using XON/XOFF and
hardware flow control using RTS/CTS are supported by the STS Series.
Software flow control method controls data communication flow by sending special characters
XON/XOFF(0x11/0x13) between two connected devices. And hardware flow control method controls
data communication flow by sending signals back and forth between two connected devices.
Note: Flow control is supported only in RS232 mode. RS422 and RS485 mode do not support any
kind of flow control method in hardware or software.